Ordering information – inlet cover, Inlet cover, Open-center directional control valve vo40 – Parker Hannifin VO40 User Manual

Page 16: 12] – max pump flow, 15] – type of inlet i, 24] to [27] – inlet porting options

Advertising
background image

12

Parker Hannifin Corporation

Open-Center Directional Control Valve
VO40

Catalog HY17-8505/UK

The inlet cover of VO40 is available in two versions. One is the standard inlet and the other is an inlet with a sole-
noid pump unloader (in development). The porting location options for the standard inlet are:
1) Top/side – inlet and outlet ports. Any unused ports can be plugged.
2) Top – inlet and outlet ports only.

All inlet bodies have a gage port, that comes plugged. SAE #4 (7/16"x20 UNF thread) or 1/4" BSP.

The coding to specify an inlet cover is accomplished by eight fields, as shown below:

[12] – Max Pump Flow

The pump inlet flow can be selected in LPM or GPM.

[15] – Type of Inlet
I

Standard Inlet.

IU

Inlet with pump unload, solenoid actuated (in development).

[24] to [27] – Inlet Porting Options

INLET

OUTLET

GAGE

TANK

TANK

OPEN

CENTER

PARALLEL
PATH

INLET

OUTLET

TANK

OPEN

CENTER

PARALLEL
PATH

INLET

GAGE

1) Standard – Top & Side Inlet/Outlet Ports

2) Standard – Top Inlet/Outlet Ports

Ordering Information – Inlet Cover

Advertising