1

Invitium Battery System BAT-24CM

About the Invitium Battery System

As a component of the Planar Invitium medical workstation, the Invitium battery
system is designed specifically for point-of care use. It is modular, compact, and
ergonomically suited for effective utilization in the medical environment.

The battery system supplies a regulated +12 VDC to the Invitium medical
workstation. It contains two sealed lead acid batteries, a medically certified universal
input power supply, universal charging control module, an AC line filter, a cooling
fan, and appropriate cabling. All components are mounted to sheet metal enclosure,
which provides mechanical strength as well as EMI/EMC protection and shielding.

The Invitium battery system is classified as follows:

Protection against electric shock: Class I and Internally Powered Equipment

Degree of protection against electric shock: No Applied Part

Degree of protection against water ingress: IPX1, Drip-Proof Equipment

At a nominal load of 50 watts, the battery system provides up to 4 hours of system
operation. The charging and monitoring electronics control the charge rate of the
battery as well as the maximum discharge level. This ensures safe operation of the
battery and prevents damage from high charge rates and low discharge levels. This
protection gives the battery a minimum cycle life of 250 fully discharged to fully
charged cycles. The output voltage regulator provides a regulated 12 volts DC at
a power level up to 72 watts. No external regulators are required.

Externally accessible fuses are provided on the charging controller module to
electrically isolate the battery from all electronic components during transportation.

See the

technical specification

for more information.

About the battery models

The model number scheme for the
battery system is BAT-xxyy, where xx
is the amp-hour rating of the battery
contained in the battery system and
yy is the mounting designator.

The mounting SA refers to stand-
alone. The battery system can be
mounted to any solid surface in
a horizontal position, using
external straps.

The mounting CM refers to cart-
mountable. The battery system can
be mounted directly onto the Planar
Orion cart.

Caution

The Invitium medical workstation is
a Class I system under the Medical
Device Directive (MDD), intended for
near-patient proximity use. It is not
intended for direct connection to
the patient.