Temp and lamp indicators, Managing the indicated problems, E 40) – Panasonic PT-AX200U User Manual

Page 40: Nglish, Jlamp indicator j temp indicator

Advertising
background image

40 -

E

NGLISH

Maintenance

TEMP and LAMP Indicators

If a problem should occur with the projector, the LAMP and/or TEMP
indicators will inform you. Manage the indicated problems as follow.

1. Confirm the status of all indicators and projector, and switch off

the projector in proper way.

2. Find out the cause of the problem by status of the LAMP and/or

TEMP indicators.

3. Follow the following instruction for each indication and solve the

problem.

4. Turn on the projector in the correct way and confirm the

indicator is not indicating a problem any longer.

J

LAMP indicator

J

TEMP indicator

Managing the indicated problems

NOTE:

• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorized Service Center.

Indicator

Illuminating red

Flashing red

Problem

LAMP RUNTIME has
reached 1 800 hours.

The lamp circuit failure, abnormal function or lamp unit is damaged.

Cause

The lamp unit will run
out soon and needs to
be replaced.

The MAIN POWER is
switched on again
before the lamp unit is
cooled enough.

The lamp circuit failure,
abnormal function.

The lamp unit is
damaged.

Remedy

See “Replacing the
lamp unit” on page 42.

Let the lamp unit cool
down and turn on the
MAIN POWER.

Contact an Authorized
Service Center.

See “Replacing the
lamp unit” on page 42.

Indicator

Illuminating red and still projecting

Flashing red and the POWER button is turned off

Problem

The temperature inside and/or outside the projector is abnormally high.

Cause

The ventilation openings are
covered.

The room temperature is too
high.

The air filter is excessively dirty
and the ventilation is poor.

Remedy

Remove the object(s) from the
ventilation openings or clear
around the projector.

Reinstall the projector in
temperature controlled place.
See page 48.

Replace the air filter in the
proper method. See page 41.

POWER LAMP TEMP