PSC PowerScan User Manual

Page 122

Advertising
background image

116

PowerScan

Scanner

Label Length

Format

Follow the steps below to set the Standard 2 of 5/IATA label length for-
mat to select either

Variable Length

or

Fixed Length

format.

Variable Length

Format

Follow the steps below to set the Standard 2 of 5/IATA symbology to
read Variable Length Format.

1.

Identify the minimum length setting you want to make. The
selectable range is 02 to 50

1

characters.

2.

Scan the SET bar code below.

3.

Scan the ENABLE VARIABLE LENGTH FORMAT bar code.

4.

Scan the SET MINIMUM LABEL LENGTH bar code.

5.

Set the minimum label length by scanning the applicable digits
on page 119. Return to this page and go to step six.

6.

Scan the END bar code.

1. For this symbology, the scanner will decode up to 50 characters , but the actual length read

will vary depending upon the interface type, and bar code physical size and quality.

NOTE

If you are setting a label length less than ten, you
must scan a zero digit first and then the length
digit (e.g., 04, 06, 08).

Variable Length Format

SET ------------------------------------------

Enable Variable Length
Format

---------

Set Minimum Label
Length

---------

END ------------------------------------------

Advertising