Symbology Options

After enabling the desired symbology, you can use the bar codes labels
in this section to configure the specific options/features required for
your site.

Code 39/PharmaCode 39

Code 39

Options

The Code 39 symbology has the following programmable features:

Check Digit

Start/Stop Characters

Code 39 Full ASCII

Minimum Label Length

Read Verification

QuadraLogic Decoding

Check Digit

Check Digit calculates the Check Digit to verify that the Check Digit
contained in the bar code label is correct. If you enable this feature,
your bar codes must contain a Check Digit.

Start/Stop

Characters

Start/Stop Characters

selects either Send or Don’t Send depending on

your host’s interface requirement.

Code 39 Full

ASCII

Code 39 Full ASCII

enables or disables the ability to decode Code 39

Full ASCII labels.

Minimum Label

Length

Minimum Label Length

sets the minimum label length required for the

Code 39 symbology. This feature causes the scanner to ignore small
label segments, reducing the possibility that a portion of a good label is
incorrectly seen as an entire label.

Read Verification

Read Verification is the number of times the scanner is required to read
the bar code data before sending the label data to the host.

QuadraLogic

Decoding

QuadraLogic Decoding directs the scanner to decode labels with wide-
spread problems of spots, voids, and/or non-uniform widths.

To optimize your scanner’s performance activate this option only for
symbologies for which it is necessary.

There are many additional ways to configure the scanner to read and
decode extremely poor labels. Contact your sales representative or ser-
vice provider for other advanced QuadraLogic Decoding settings.