QS2500

Numeric Key:

If your application accepts only keypad numeric code, use

setting

01

to make the QS2500 output code as numeric-keypad presses

when it reads digits. If you use setting

02

, the scanner will send the three

digit ACSCII number for all data using the Alt and numeric keypad key-
codes. Setting

02

prevents the caps Lock from affecting scanner data.

Caps Lock:

By selecting Caps Lock or No Caps Lock, the QS2500 can get

Caps Lock status.

Power-On Simulation:

All PCs check the keyboard status during the power-

on selftest. It is recommended that you enable this function if you are
working without a keyboard installation. It simulates keyboard timing and
passes the keyboard status to the PC during power-on.

Intercharacter Delay:

This delay is inserted after each data character trans-

mitted. If the transmission speed is too high, the system may not be able
to receive all characters. You may need to adjust the delay to make the sys-
tem work properly.

Block Transmission Delay:

This is a delay timer between bar code data out-

puts. The feature is used to transfer continually with shorter bar code data
or multifield scanning.