Technical data, S i g 5 0 4 – Parkinson Cowan SIG 504 User Manual

Page 36

Advertising
background image

TECHNICAL DATA

DIMENSIONS

Height

Width

Depth

Height to hotplate

900mm (nominal)

600mm (nominal)

600mm
(to front of
door panel)

Space for fixing at hotplate level

2mm minimum clearance

Space for fixing above hotplate level

Flush-see important note 'Location of Appliance' page 38

Minimum space above hotplate

787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).

Weight of appliance

63.5kg.

Minimum distance from rear wall

5mm (spacer given by pressed spacer on vent panel).

CONNECTIONS

Gas

Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).

Electric

220V/240V 50 Hz mains 3 core cable is supplied with an integral,

moulded plug fitted with a 3 amp fuse.

IGNITION

Spark generator

APCO 6+1 MG 7424/1

GRILL

Natural Gas

L.P.Gas

Heat Input

3.3kW (11263 Btu/h)

3.0kW (215 g/h)

Injector Marking

138

088

HOTPLATE

Natural Gas

R.H.F.

R.H.R.

L.H.R. L.H.F

Heat Input

1.0kW

2.0kW

2.0kW 2.8kW

(3412 Btu/h) (6824 Btu/h) (6824 Btu/h) (9554 Btu/h)

Injector Marking

079

104

104

130

L.P.Gas

R.H.F.

R.H.R.

L.H.R.

L.H.F.

Heat Input

1.0kW

2.0kW

2.0kW

2.7kW

(71.85 g/h)

(143.7 g/h)

(143.7 g/h)

(194 g/h)

Injector Marking

051

072

072

083

36

S I G 5 0 4

Advertising