3 converter check point – Planet Technology Media Converter Chassis MC-1000R User Manual

Page 13

Advertising
background image

12

4.3 Converter Check point

Fiber
Port

Attach the fiber cable. The Tx,
Rx fiber cable must be paired at
both ends

2.5mm
DC Receptacle

2.5mm

+5V for each slot

DC receptacle is 2.5mm
wide that conforms to
and matches the Media
Converter 2.5mm DC
jack’s central post. Do
not install any improper
unit, model of the Media
Converter

TP
Port

Attach UTP Cat. 3 or 5 cable to
TP port
MPR: To a Hub or Repeater
DTE: To a workstation or NIC

Slide switch “DTE”/”MPR” is on
the side panel. Default: MPR

BNC
Port

Attach T-Connector to BNC port
and connect the RG-58 coaxial
network.
Ensure

the

coaxial

cable/

segment is terminated at both
ends properly.

Note

For safety reason, it is recommend storing the AC
adapter of the converter in a known secured place. For
more about converter, refer to the user guide of the
converter.