Wall mount application – POSIFLEX Business Machines PP5600 SERIES User Manual

Page 19

Advertising
background image

2 - 7

clearance will vary. This clearance can be observed from the
offset pattern printed in bottom of self test.

Whenever the lower part of the long vertical lines is shifted

horizontally away from the upper part by about one dot width, the
offset value should be adjusted to move it back for decent print if
bi-directional print is engaged. Increasing the offset value by
changing the S1 setting can move the lower part to right and
decreasing the value moves the lower part to left.

b.Printer general setting – S2

Switch

Function

ON

OFF

2-1 Hand shaking mode X-ON/X-OFF

DTR/DSR

2-2

Data bit

7-bit data

8-bit data

2-3

Parity check

Parity check

No parity check

2-4

Parity selection

Even parity

Odd parity

2-5

Baud rate (bps)

4800

9600

2-6

Busy on

Buffer full Off line or Buffer full

2-7

Column spacing

(columns per line)

2 half dots

(42 / 35)

3 half dots

(40 / 33)

2-8

Print direction

Uni-direction

Bi-direction

Positions 1 to 6 of the S2 switch define the communication

protocol and handshaking criteria in RS232 interface. They will
present no influence if parallel interface is used.

Position 7 of S2 alters the horizontal spacing between

characters to get different print density on same font format.

Position 8 of S2 determines whether to print only in one

direction of print head operation or in both directions.

All positions of S2 default to OFF when printer delivered.

3.

Wall mount application

In wall mount application, the paper near end sensor will

not have proper operation and it is suggested not to install it.

Advertising