1.2. INSTALLATION

CLEARANCES

The clearances shown below are for combustible and non-combustible installations and will allow for
safe and proper operation of your appliance.

In addition to the above clearances there must also be at least 16 inches (40.64cm) of aisle space in
front of the unit.

Combustible Construction

Non Combustible Construction

Inches (centimeters)

Inches (centimeters)

Back

6.0" (15.24cm)

0.0" (0.0cm)

Sides

6.0" (15.24cm)

0.0" (0.0cm)

Counter

6.0" (15.24cm)

6.0" (15.24cm)

WARNING

DO NOT sit or stand on this appliance. The appliance’s front panel, tank,
splash back, tank cover, workshelf, drain board is not a step. Serious
injury could result from slipping, falling or contact with hot liquids.

WARNING

DO NOT install this appliance next to a deep fat fryer. A splash over of water into the hot oil may
cause a flash fire.

WARNING

DO NOT obstruct the flow of ventilation, or air openings around the appliance. Adequate
clearance around the appliance is necessary for servicing and proper component ventilation.
Ensure that you meet the minimum clearance requirements specified in this manual.

CAUTION

To prevent equipment damage and/or personal injury, do not tilt the appliance onto any two of its
casters or legs, or pull the appliance by the splash back.