3.0 Operating the Boiler

6

3.2

Temperature Control

1. Central Heating: The central heating hot water

flow temperature can be adjusted between 30° C

(± 5° C) minimum and 85° C (± 5° C) maximum.

2. Turn the control knob clockwise to increase the

temperature (Fig. 9).

3. In normal winter usage we recommend that the

central heating temperature be set at maximum.

4. Domestic Hot Water Pre-Heat: To enjoy

optimum performance of the boiler the pre-heat

control should be set fully clockwise to the ON

position (Fig. 10). When there is a demand for hot

water it will be supplied at approximately 65° C

instantaneously.

5. Turning the control 15° clockwise from the OFF

position will activate the pre-heat feature. Hot

water will be supplied at approximately 35° C

instantaneously.

6. To increase the temperature turn the control

further clockwise. For example, when set 90°

clockwise the boiler will supply hot water at

approximately 44° C instantaneously. At a

position 180° from clockwise (i.e. straight down)

the hot water will be supplied at 52° C

instantaneously.

7. When the control is set anywhere between 15°

clockwise from the OFF position and the ON

position, the pre-heat feature will operate.

8. With the control in the OFF position (Fig. 11)

the pre-heat feature will not operate. Hot water

will be supplied at approximately 50° C.

9. The pre-heat feature will function with the

selector switch in either operating position. This is

indicated by the domestic hot water mode neon

flashing (Fig. 12).

10. The flow rate can be reduced down to as low

as 2.5 litre/min. The boiler will still recognise the

need to heat the water.

3.3

Flame Failure Reset

1. The red flame failure neon (

) will illuminate in

the event of the burner failing to light, or when

incomplete lighting of the burner occurs (Fig. 12).

2. Turn the selector switch fully anti-clockwise

against the spring pressure to the reset position

(

R

) and release (Fig. 13). Set the selector to the

required position to light the boiler.

3. If the flame failure light illuminates repeatedly a

fault is indicated. Your Service Engineer should

be contacted as soon as possible.

OFF

ON

PREHEAT

Domestic Hot Water

Pre-Heat Control

ON Position

Fig. 9

Central Heating

Temperature Control

Fig. 10

Reset Position

Fig. 13

30

°

40

°

50

°

60

°

70

°

80

°

Flame Failure
Neon

Fig. 12

OFF

ON

PREHEAT

Fig. 11

Domestic Hot Water

Pre-Heat Control

OFF Position

Domestic Hot
Water Neon