Purity and Convergence Procedure

Adjustment is necessary only if the CRT or the
deflection yoke is replaced or if the setting was
disturbed. The complete procedure consists of:
1.

Vertical Raster Shift Adjustment. (Only for Models
with Purity/Convergence Assembly with 4 Pairs
of Rings)
.

2.

Initial static convergence.

3.

Setting the purity.

4.

Final static convergence.

When the CRT or the Yoke is Replaced

Place the yoke on the CRT neck (do not tighten
the clamp).
Place the vertical raster shift tabs at 3 o’clock (90

o

from

the purity and convergence tabs)

Turn the Receiver ON. Operate the Receiver for 60
minutes using the first Purity Check field (white screen)
to stabilize the CRT.

Fully degauss the Receiver by using an external
degaussing coil.

Slide the deflection yoke back and forth on the neck of
the CRT until it produces a near white, uniform raster.

Vertical Raster Shift Adjustment

(Only for

Models with Purity/Convergence Assembly with 4
Pairs of Rings)
.
Apply a green pattern with a horizontal line, adjust the
Deflection Yoke so that has no tilt, then secure it.
Adjust center line of the pattern with the mechanical
center of the CRT, this center is determined by two
marks at the side edges of the screen. To adjust the
line, once the vertical raster shift tabs are place at 3
o’clock to reduce its magnetic field effect (see Fig. 9
and Fig. 10) open the tabs the same angle from the
center, until the center line of the pattern becomes a
straight line, centered with the marks of the CRT. (see
Fig. 11)

G3

G4

Purity Rings Centered
Over G3/G4 Gap

R&B Convergence Rings

R&B&G Convergence Rings

Vertical Raster Shift Ring

Figure 9.

Positioning of Purity/Convergence

Assembly (4 Pairs of Rings)

90

o

Purity Rings

Vertical Raster

R&B Convergence Rings

R&B&G Convergence Rings

Figure 10.

Positioning of Purity/Convergence

Assembly (4 Pairs of Rings)

Shift Rings

Vertical Raster Shift tabs

Open the

same angle
from center

Figure 11.

Vertical Raster Shift Adjustment

(4 pairs of rings assembly)

Center Marks

from pattern

Center line