Press the Power Button on the Remote Control to select the Serviceman Adjustment

For Adjustments:

X Option Adjustment

Default

Level

X00

V ENHANCER

3

X01

V ENH NL

1

X02

H PEAKING GAIN

2

X03

V CORING

1

X04

C TRAP GAIN

0

X05

GEO MAG CEN

179

X06

GEO MAG GAIN

10

X07

H LOCK

1

X08

H LOCK L

70

X09

H SEPA 1L

313

X0A

H SEPA 2L

266

X0B

H LOCK W

0

X0C

H LOCK L

70

X0D

H SEPA 1WL

313

X0E

H SEPA 2WL

266

E Option Adjustment

Default

Level

E00

SURROUND EFFECT

3

E01

BBE LOW

4

E02

BBE HIGH

6

1.Press Channel Up/Down on the

Remote Control to select one of
the available Service Adjustments
(a in Fig. 20).

Note: Write Down the original

value set (b in Fig. 20) for
each address before
modifying anything. It is
easy to erroneously adjust
the wrong item.

2.Press Volume Up/Down on the

Remote Control to adjust the
level of the selected Service
Adjustment (b in Fig. 20).

CH

CH

PW

PW

To B Items.

CH

CH

Advertising