Lamp unit replacement procedure, 65 other s 64-e – Panasonic PT-L780E User Manual

Page 33

Advertising
background image

E

NGLISH

-65

Other

s

64-E

NGLISH

+ Press the ENTER button and

select the “LAMP RUN TIME” by
pressing the
F or G buttons.

, Press and hold the ENTER

button for approximately 3
seconds.

The “Lamp Time Reset” will be
displayed.

- Select “OK” by pressing the

I

I or H

H buttons and press the

ENTER button.

NOTE:
B If “CANCEL” is selected in step

-, the operation for resetting the
lamp time will be cancelled.

. Turn off the power.

This will reset the cumulative
usage time for the lamp unit to
zero.
Refer to steps % and & on page
29 for details on how to turn off
the power.

' Close the air outlet port, and

then use a Phillips screwdriver
to securely tighten the air
outlet port fixing screws.

NOTE:
B Be sure to install the lamp unit

and the air outlet port securely. If
they are not securely installed, it
may cause the protection circuit
to operate so that the power
cannot be turned on.

( Insert the mains plug into the

mains socket and then press
the MAIN POWER switch.

NOTE:
B If the POWER indicator on the

projector does not illuminate red
when the MAIN POWER switch is
turned on, turn the MAIN POWER
switch off again and check that
the lamp unit and the air outlet
port are securely installed. Then
turn the MAIN POWER switch
back on.

) Press the POWER button so

that a picture is projected onto
the screen.

* Press the MENU button to

display the MENU screen, and
select “OPTION” by pressing
the
I

I or H

H buttons.

OPTION

SHUTTER

OSD

AUTO KEYSTONE

RGB/YPbPr

RGB2 SELECT

BACK COLOR

FRONT/REAR

DESK/CEILING

LAMP POWER

LAMP RUN TIME

NEXT PAGE @

1820 H

OFF

OFF

RGB

INPUT

BLUE

FRONT

DESK

LOW

ON

ON

YPbPr

OUTPUT

BLACK

REAR

CEILING

HIGH

SELECT:[{][}]

ADJUST:[{][}]

ENTER:[ENTER]

ESC:[MENU]

OPTION

SHUTTER

OSD

AUTO KEYSTONE

RGB/YPbPr

RGB2 SELECT

BACK COLOR

FRONT/REAR

DESK/CEILING

LAMP POWER

LAMP RUN TIME

NEXT PAGE @

1820 H

OFF

OFF

RGB

INPUT

BLUE

FRONT

DESK

LOW

ON

ON

YPbPr

OUTPUT

BLACK

REAR

CEILING

HIGH

SELECT:[^][@]

ADJUST:[{][}]

ENTER:[ENTER]

ESC:[MENU]

Power OFF

OK

CANCEL

Lamp Time Reset

Lamp unit replacement procedure

NOTE:
B If the lamp usage time has passed 1 500 hours (when LAMP POWER has

been set to “HIGH”), the projector will switch to standby mode after
approximately 10 minutes of operation. The steps ) to . on the next
page should thus be completed within 10 minutes.

# Turn off the MAIN POWER

switch according to the
procedure given in “Turning off
the power” on page 29, and
then disconnect the mains plug
from the mains socket and
check that the area around the
lamp unit has cooled down.

$ Use a Phillips screwdriver to

turn the air outlet port fixing
screws at the back of the
projector, and then open the air
outlet port.

% Use a Phillips screwdriver to loosen

the two lamp unit fixing screws until
the screws turn freely. Then hold
the handle of the lamp unit and
gently pull it out from the projector.

& Insert the new lamp unit while

making sure that the direction
of insertion is correct, and then
use a Phillips screwdriver to
securely tighten the lamp unit
fixing screws.

Air outlet port

Handle

Air outlet port fixing screws

Lamp unit fixing screws

Lamp indicator warning
light

On-screen display

The projector will enter
Standby Mode and the
red indicator lamp will
illuminate.

Displayed for 30
seconds. Pressing any
button will clear the
display.

More than 1 300 hours

This display cannot be
cleared at all, no matter
which button is pressed.

More than 1 500 hours

Advertising
This manual is related to the following products: