123

FX-305

SPECIFICATIONS

I/O CIRCUIT

DIMENSIONS (Unit: mm

in

)

Amplifier

FX-305
FX-305P

2.5

0.098

Digital display (Red)

Jog switch

MODE key

0.7

0.028

Output 1 operation indicator
(Orange)

Output 2 operation indicator
(Orange)

8.3

0.327

27.8

1.094

7

0.276

36.5

1.437

64.5

2.539

Communication
window

10.5

0.413

3.95

0.156

3.3

0.13

7

0.276

7

0.276

Beam-
emitting
part

Beam-
receiving
part

10

0.394

30

1.181

3

0.118

13.5

0.531

3

0.118

48.2

1.898

12

0.472

26.3

1.035

Suitable for 35 mm

1.378 in

width DIN rail

Notes: 1) The quick-connection sub cable does not have

ם

V (brown) and 0 V (blue).

The power is supplied from the connector of the main cable.

2) 25 mA max., if five amplifiers, or more, are connected together.

Symbols … D: Reverse supply polarity protection diode

Z

D1

, Z

D2

: Surge absorption zener diode

Tr

1

, Tr

2

: NPN output transistor

Notes: 1) The quick-connection sub cable does not have

ם

V (brown) and 0 V (blue).

The power is supplied from the connector of the main cable.

2) 25 mA max., if five amplifiers, or more, are connected together.

Symbols … D: Reverse supply polarity protection diode

Z

D1

, Z

D2

: Surge absorption zener diode

Tr

1

, Tr

2

: PNP output transistor

Color code of quick-connection cable

D

Z

D1

T

r

1

T

r

2

50 mA max. (Note 2)

Z

D2

D

Z

D1

T

r

1

T

r

2

Z

D2

1

3

4

2

1

3

4

2

Color code of quick-connection cable

Terminal No.

Terminal No.

NPN output type

PNP output type

FX-305P

FX-305

50 mA max. (Note 2)

Sensor circuit

Users’ circuit

Internal circuit

Users’ circuit

Internal circuit

50 mA max. (Note 2)

(Blue) 0 V (Note 1)

(Brown)

ם

V (Note 1)

(Black) Output 1

(White) Output 2

ם
מ

12 to 24 V DC

ע

10 %

Load

Load

(Blue) 0 V (Note 1)

(Brown)

ם

V (Note 1)

(Black) Output 1

(White) Output 2

50 mA max. (Note 2)

Load

Load

ם
מ

12 to 24 V DC

ע

10 %

Sensor circuit

Type

NPN output

FX-305

PNP output

FX-305P

12 to 24 V DC

ע

10 % Ripple P-P 10 % or less

Selectable either Light-ON or Dark-ON, with jog switch

Incorporated

4-digit red LED display

Incorporated

35 to 85 % RH, Storage: 35 to 85 % RH

Red LED (modulated)

Connector (Note 4)

Extension up to total 100 m

328.084 ft

is possible with 0.3 mm

2

, or more, cable.

20 g approx.

Model No.

Item

Supply voltage

Power consumption

Response time
(Note 2)

Digital display

Sensitivity setting

Fine sensitivity adjustment function

Timer function

Automatic interference prevention
function (Note 2) (Note 3)

Ambient temperatu-
re

Ambient humidity

Emitting element

Material

Connecting method

Cable extension

Weight

Output operation

Short-circuit protection

Enclosure: Heat-resistant ABS, Transparent cover: Polycarbonate
Press switches: Acrylic, Jog switch: Heat-resistant ABS

Incorporated [Up to 4 sets of fiber heads can be mounted close together
(However, U-LG mode is 8 sets, H-SP mode is 2 sets.)]

H-SP: 65 !s or less, FAST 150 !s or less, STD: 250 !s or less, STDF: 700 !s or less,
LONG: 2.5 ms or less, U-LG: 4.5 ms or less selectable with jog switch

Incorporated with variable ON-delay / OFF-delay / ONE-SHOT / ON-delay

⅐OFF-

delay / ON-delay

⅐ONE-SHOT timer, switchable either effective or ineffective

(Timer period Output 1: 0.5 ms, 1 to 9999 ms, Output 2: 0.5 ms, 1 to 500 ms)

Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)

NPN open-collector transistor

• Maximum sink current: each 50 mA (Note1)

• Applied voltage: 30 V DC or less

(between output and 0 V)

• Residual voltage: 1.5 V or less

[at each 50 mA (Note 1) sink current]

PNP open-collector transistor

• Maximum source current: each 50 mA (Note1)

• Applied voltage: 30 V DC or less

(between output and

ם

V)

• Residual voltage: 1.5 V or less

[at each 50 mA (Note 1) source current]

Notes: 1)

2)

3)

4)

50 mA per output. 25 mA if five, or more, amplifiers are connected
in cascade.
When the interference prevention function ‘ ’ is set, the number
of mountable fibers becomes double. Furthermore, take care that
the response time also becomes double.
When the power supply is switched on, the light emission timing is
automatically set for interference prevention.
The cable for amplifier connection is not supplied as an accessory.
Make sure to use the optional quick-connection cables given below.
Main cable (4-core): CN-74-C1 (cable length 1 m

3.281 ft

), CN-74-C2 (cable length 2 m

6.562 ft

)

CN-74-C5 (cable length 5 m

16.404 ft

)

Sub cable (2-core): CN-72-C1 (cable length 1 m

3.281 ft

), CN-72-C2 (cable length 2 m

6.562 ft

)

CN-72-C5 (cable length 5 m

16.404 ft

)

CN-73-C

and CN-71-C□ cannot be used.

Thru-beam type (FT-B8): 1,700 (U-LG), 1,100 (LONG), 730 (STDF)

530 (STD), 400 (FAST), 200 (H-SP)

Reflective type (FD-B8): 600 (U-LG), 480 (LONG), 280 (STDF)

220 (STD), 160 (FAST), 85 (H-SP)

Normal mode: 2-level teaching / Limit teaching / Full-auto teaching /

Max. sensitivity teaching / Manual adjustment

Window comparator mode: Teaching (1-level / 2-level / 3-level) /

Manual adjustment

Sensing range
(mm)

מ

10 to

ם

55 °C

ם

14 to

ם

131 °F

If 4 to 7 units are connected in cascade:

מ

10 to

ם

50 °C

ם

14 to

ם

122 °F

,

if 8 to 16 units are connected in cascade:

מ

10 to

ם

45 °C

ם

14 to

ם

113 °F

(No dew condensation or icing allowed),
Storage:

מ

20 to

ם

70 °C

מ

4 to

ם

158 °F

(

)

PRECAUTIONS FOR PROPER USE

This product is not a safety sensor. Its use is not intended or designed
to protect life and prevent body injury or property damage from
dangerous parts of machinery. It is a normal object detection sensor.

Output
(Output 1, Output 2)

All information is subject to change without prior notice.