Fx-301, List of fibers – Panasonic Digital Fiber Sensor FX-301 User Manual

Page 8

Advertising
background image

75

FX-301

R25 mm

R0.984 in

R25 mm

R0.984 in

600

23.622

300

11.811

220

8.661

מ

120

4.724

60

2.362

40

1.575

מ

120

4.724

60

2.362

40

1.575

מ

80

3.150

35

1.378

10

0.394

מ

3

0.118

2

0.079

1

0.039

מ

14

0.551

7

0.276

4

0.157

מ

130

5.118

64

2.520

45

1.772

מ

300

11.811

150

5.906

110

4.331

מ

60

2.362

30

1.181

20

0.787

מ

60

2.362

30

1.181

20

0.787

מ

מ

מ

מ

מ

1

0.039

מ

מ

מ

6

0.236

3

0.118

2

0.079

מ

64

2.520

32

1.260

22

0.866

מ

"

0.25 mm

"

0.010 in

opaque object

Horizontal:

"

0.025 mm

"

0.0010 in

opaque object
Vertical:
"

0.45 mm

"

0.018 in

opaque object

"

0.06 mm

"

0.0024 in

opaque object

"

0.02 mm

"

0.0008 in

opaque object

"

0.02 mm

"

0.0008 in

opaque object

"

0.05 mm

"

0.0020 in

opaque object

LIST OF FIBERS

Special use

Wide beam

Arr

a

y

Narro

w beam

Ultr

a-small diameter

Tough fle

xib

le

FT-A8

FT-AFM2

FT-AFM2E

FT-K8

FT-KV8

FT-KV1

FT-E12

FT-E22

FT-P81X

Special use fibers [Thru-beam type (one pair set)]

1,100

43.307

220

8.661

200

7.874

800

31.496

8

0.315

36

1.417

230

9.055

:LONG
:STD

:FAST
:S-D

Sensing range (mm

in

) (Note 1)

Red LED

Blue LED Green LED Infrared LED

Allowable
bending
radius

Model No.

3,500

137.795

1,500

59.055

750

29.528

650

25.591

330

12.992

115

4.528

590

23.228

290

11.417

100

3.937

2,000

78.740

1,000

39.370

350

13.780

18

0.709

10

0.394

3

0.118

180

7.087

500

19.685

250

9.843

100

3.937

80

3.150

50

1.969

15

0.591

650

25.591

320

12.598

110

4.331

220

8.661

110

4.331

80

3.150

מ

48

1.890

24

0.945

18

0.709

מ

48

1.890

24

0.945

18

0.709

מ

מ

מ

מ

מ

4

0.157

2

0.079

1.5

0.059

מ

10

0.394

5

0.197

3

0.118

מ

130

5.118

64

2.520

45

1.772

מ

Sensing width
32 mm

1.260 in

W5

ן

H69

ן

D20

W0.197

ן

H2.717

ן

D0.787

Sensing width
11 mm

0.433 in

W4.2

ן

H31

ן

D13.5

W0.165

ן

H1.220

ן

D0.531

Top sensing
W5

ן

H15

ן

D15

W0.197

ן

H0.591

ן

D0.591

Side sensing
W5

ן

H15

ן

D15

W0.197

ן

H0.591

ן

D0.591

Side-view

Beam diameter:

"

0.125 mm

"

0.005 in

Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the

infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.

Notes:

2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using

amplifiers other than red LED type.
The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent
condition.

Notes:

3) The fiber cable length practically limits the sensing range to 3,500 mm

137.795 in

long.

R5 mm
R0.197 in

R10 mm
R0.394 in

R10 mm
R0.394 in

R10 mm
R0.394 in

R10 mm
R0.394 in

Sleeve part cannot be bent.

Beam diameter:

"

0.25 mm

"

0.010 in

Sleeve part cannot be bent.

Lens mountable

Type

Shape of fiber head

(mm

in

)

500 mm

19.685 in

1 m

3.281 ft

1 m

3.281 ft

Min. sensing object

under the optimum
condition (Note 2)

3,500

137.795

3,500

137.795

3,500

137.795

3,500

137.795

(Note 3)

2,400

94.488

1,200

47.244

700

27.559

מ

1,200

47.244

600

23.622

350

13.780

מ

800

31.496

400

15.748

240

9.449

מ

400

15.748

200

7.874

130

5.118

מ

200

7.874

100

3.937

65

2.559

מ

150

5.906

75

2.953

40

1.575

מ

"

0.3 mm

"

0.012 in

opaque object

FT-A30

2 m

6.562 ft

2 m

6.562 ft

2 m

6.562 ft

2 m

6.562 ft

2 m

6.562 ft

Side-view
W2

ן

H1.5

ן

D20

W0.079

ן

H0.059

ן

D0.787

Fiber cable
length

: Free-cut

08/2005

Advertising