Ventilation lever, Recommended – Panasonic CW-C200KR User Manual

Page 3

Advertising
background image

9.2.1. Parts Identification.

9.2.1.1.

Vertical Airflow Direction Vane.

Airflow direction adjustment Up-and-Down.

The vertical airflow direction vane is

controlled by positioning the vane to

discharge the air upwards, downwards

or straight out.

9.2.1.2. Ventilation Lever.

When the slide lever is in the:

“OPEN” position, the ventilation door

opens to allow air, smoke or odours to be

expelled from the room.

“CLOSE” position, the ventilation door is

closed and the air will be circulated inside

the room and conditioned.

9.2.1.3. Recommended.

Use the air conditioner under the following conditions:

Operating temperature range.

Indoor side

Outdoor side

D.B.T. W.B.T. D.B.T. W.B.T.

Cooling Maximum Temperature

32°C

23°C

43°C

26°C

Minimum Temperature

21°C

15°C

21°C

15°C

Heating Maximum Temperature

27°C

----

21°C

15°C

Minimum Temperature

20°C

----

-5°C

-6°C

D.B.T.: Dry Bulb Temperature
W.B.T.: Wet Bulb Temperature

Note: Humidity may exceed 90%.

Continuous operation at humidities of over 90% may
create condensation to form on the intake and outlet
vanes.