How to operate – Panasonic CW-C200KR User Manual

Page 4

Advertising
background image

9.2.2. How to Operate.

(1) Open the Control Panel Cover.

Fig. 1

(2)

Power Supply
Switch off the breaker and set the Main Control Knob to the
OFF position before connecting the power plug cord to an
independent power supply.

Fig. 2

(3)

Main Control Knob
Set the Main Control Knob to either LOW COOLING or
HIGH COOLING and LOW HEATING or HIGH HEATING
as desired, FAN setting operates the fan only.

Caution: If the Main Control Knob is turned off or
changed to a fan setting from a cooling or heating
operation setting, WAIT at least 3 minutes before
resetting to cooling or heating operation.

Fig. 3

(4)

Thermostat Control Knob
Turn the Thermostat Control Knob as shown in Fig. 4.
Usually “6” ~ “7” is the recommended setting position for
cooling and “4” ~ “5” for heating.

Note: When the Thermostat Control Knob is set to “10”,
moisture may freeze onto the evaporator fins and prevent
effective cooling. If this happens, turn the Main Control
Knob to FAN, and the Thermostat Control Knob
counterclockwise. This will quickly defrost the evaporator
fins so that normal cooling can be resumed.

Fig.4

(5) Air Swing Switch

(Airflow direction adjustment side-to-side)

To obtain a fixed airflow direction, set the Air Swing Switch
to “ON” for the vanes to swing from side to side until the
desired flow direction is reached, then switch it to “OFF”.

For continuous side-to-side air circulation, set the Air Swing
Switch to “ON”.

Fig. 5

15

Main Control

knob

Thermostat
control knob

Air Swing Switch

CW-C170KR / CW-C200KR / CW-C240KR / CW-A170KR / CW-A200KR / CW-A240KR

Advertising
This manual is related to the following products: