DATA Port Connection (PS

Data)

Data ports are connected with RS-485 cables among devices using the PS

Data protocol as follows.

Notes:

When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485

communication.

• Internal Diagram

• Basic Connection

Example 2

shows 4 Data Multiplex Units connected with 16 combination cameras, and 4 System Controllers.

System Controller WV-CU

360

System Controller WV-CU

360

UP

L

R

DOWN

System Controller WV-CU

360

Data Multiplex Unit WJ-MP204C

Data Multiplex Unit WJ-MP204

Data Multiplex Unit WJ-MP204

WJ-MP204C

WV-CU360C

4 cameras can be connected to one Data Multiplex Unit

UP

L

R

DOWN

UP

L

R

DOWN

Up to 4 Data Multiplex Units

Up to 4 System Controllers

Channel 1

Channel 2

Channel 4

Channel 13

Channel 14

Channel 16

Unit
address 1

Controller
No. 1

Controller No. 2

Controller No. 4

Unit
address 2

Unit
address 4

See page 16 for MODE switch and

CONTROLLER NO. switch settings.

DATA

Data Multiplex Unit

WJ-MP204C

System Controller

WV-CU360C

DATA

RS-485 Cable

Termination:
ON

Termination:
ON

Data Flow

WJ-MP204C

WV-CU360C

WJ-MP204C

WV-CU360C

WJ-MP204C

WV-CU360C

WJ-MP204C

WV-CU360C

1

6

1

6

No.

No.

1

1

2

2

3

3

4

4

5

5

6

6

Name

GND

TX(B)

TX(A)

RX(B)

RX(A)

GND

Controller end

TX (B)

TX (A)

RX (A)

RX (B)