Customer display – POSIFLEX Business Machines 16560900020 User Manual

Page 18

Advertising
background image

Part 18

LAN Wake up: Power Management -- Wake-Up by PCI card
RING Power Management -- Power On by Ring
Time Power Management -- Resume by Alarm

this forced power off, please disconnect the UPS battery if installed and the
AC power supply for few minutes. This may reset all hardware registers.

This switch can also be programmed as an ON only switch. That

means, if the application program issues a command compliant with the KS
series technical manual, this switch will always turn the system on when
activated, but will not power off the system when pushed again (the forced
power off feature will not work in this mode). When using this feature, please
make sure that the software application has the ability to power off the
machine. In preloaded Windows, “Posiflex Power Switch Manager” in
“Posiflex Tools” in the Program Files helps managing these functions.

Software Support Features

The KS series provides a software power off command for application

program maneuvers. The KS also provides a specific means for the software to
detect if the system is working on external or UPS battery power. Due to this
feature, compatible software applications have the ability to change operating
conditions when running on standard/backup power. The software programmer
may take reference from the KS technical manual to apply such features.

Automatic Power On Control

The system may also turn on according to some preset conditions

such as Modem Ring Up and Alarm Clock Wake Up or LAN Wake Up.

To utilize Modem Ring Up or Alarm Clock Wake Up function, the

user should enter the BIOS setup by pressing “Del” key at system boot up,
choose in “Power Management Setup” and make the “Power On by Ring”
enabled for Modem Ring Up or enable the “Resume by Alarm” for Alarm
Clock Wake Up. Save the configuration and exit the BIOS setup program. The
Preset Power On Control will then be ready. For LAN wakeup, the item
“Wake-Up by PCI card” must be enabled in “Power Management Setup” and
an operating caller system connected through LAN to the system is required. It
also requires a qualified networking technician to check the LAN chip ID of
the system for the caller system to wake up.

When the KS system is turned off after a successful boot up, the

preset automatic power on functions will keep monitoring for the preset
conditions and turn on the system when the preset conditions are met.

Please note that if the KS system is improperly turned off before a

complete boot up procedure, the above preset power on control functions will
be disabled until next turning off after a complete boot up.

CUSTOMER DISPLAY

Please follow the instructions on the manual that comes along with

the customer display when it is installed.

Advertising