1 preparing for configuration, 1 connecting a pc or terminal to the rs-232 port, 2 terminal emulation setup program – Planet Technology FGSW-2620PVS User Manual

Page 12: Console configuration

Advertising
background image

3. CONSOLE CONFIGURATION

Unlike the unmanaged switch, the FGSW-2402PVS/ FGSW-2620PVS/FGSW-2612PVS perform series smart functions that

make the Switch operate more effectively. This section will describe the common usage of the Switch Smart Con-figuration.

Note:

The following section will base on the console screens of FGSW-2620PVS. For FGSW-2402PVS and

FGSW-2612PVS, the display will be the same to FGSW-2620PVS.

3.1 Preparing for configuration

3.1.1 Connecting a PC or Terminal to the RS-232 Port

When you are ready to configure the smart functions of the Switch, make sure you had connected the supplied RS-232 serial

cable to the RS-232 port at the front panel of your Switch and your PC.

3.1.2 Terminal Emulation Setup Program

In Windows 98/2000/XP, launch "HyperTerminal", create a new connection, and adjust settings as below:

Emulation: VT-100 compatible

Baud per second: 9600

Data bits: 8

Parity: None

Stop bits: 1

Flow Control: None

To get a demonstration, please see the figure 3-1.

Figure 3-1 Console Port Settings for smart functions

Advertising
This manual is related to the following products: