Python LIQUID COOLED MILLERMATIC COMPATIBLE 248-8XX User Manual

Page 17

Advertising
background image

Liquid Cooled Millermatic Compatible™ Python

®

Owner's Manual - Page 6

Optional Barrels - Liquid Cooled

6" Straight ..........................................................................................

003-2315

6" Curved, 45° ...................................................................................

003-2316

12" Straight .......................................................................................

003-2318

12" Curved, 45° ................................................................................

003-2319

18" Straight .......................................................................................

003-2320

18" Curved, 45° .................................................................................

003-2321

Barrel Removal and Installation

CAUTION:

Power-off the coolant pump before removing or loosening

liquid-cooled cups and barrels.
To remove the barrel assembly, loosen the patented EZ Lock™ taper lock nut

until it is clear of the threads. Pull barrel out of the gun body.
To replace a barrel assembly, push the barrel assembly into the gun body

until it clicks to a stop. To assure proper seating of the barrel, open the drive/

idler roll door in the top of the handle. The rear face of the barrel should

now be flush with the gun body. Take care not to damage the o-rings when

inserting into the body. Tighten taper lock nut assembly firmly so that barrel

cannot rotate while welding.
Barrel Rotation

To rotate a barrel assembly, loosen the patented EZ Lock™ taper lock nut

assembly no more than 1 turn. Rotate barrel to the position of your choice

and re-tighten taper lock nut assembly firmly so that the barrel cannot rotate.

CAUTION:

Do not attempt to weld without the barrel being tightly

secured in the gun body, or damage to the barrel or body may result.

Section D

Maintenance

Periodic Maintenance

Your liquid cooled Millermatic Compatible™ Python

®

is designed to provide

years of reliable service. Maintenance of the gun will normally consist of a

general cleaning of the wire guide system, including barrels, drive rolls, and

conduits at regular intervals.
Remove spatter build-up from inside of nozzles with a hardwood stick.
The only parts that are subject to normal wear are the conduit, contact tips,

nozzles, barrel liners, wire guides, drive and idler rolls. A supply of these

parts should be maintained on hand.
The number of units in operation and the importance of minimal down time

will determine to what extent spare parts should be stocked on hand. See

the recommended spare parts list for the most commonly replaced parts.
It is recommended that you blow out your conduit each time you install a new

spool of wire.
If repairs do become necessary, qualified shop maintenance personnel can

easily replace any part.
Reference the table below for suggested Maintenance Tools used with the

liquid cooled Millermatic Compatible™ Python

®

welding gun.

Maintenance Tools

Tool

Part Number

Drive Roll Removal Tool

931-0100

Tip Removal Tool

931-0002

Disconnect Power

Before Maintaining.

Advertising