Python LIQUID COOLED MILLERMATIC COMPATIBLE 248-8XX User Manual

Page 20

Advertising
background image

Liquid Cooled Millermatic Compatible™ Python

®

Owner's Manual - Page 9

Troubleshooting Table

Symptoms

Cause

Remedy

No wire feed at

gun, feeder not

operating, i.e. no

slave motor or

brake solenoid.

Circuit breaker in feeder/

control box open.

Reset.

Micro-switch defective/not

being activated.

Replace switch. Check

switch for operation.

Broken electrical cable.

Check micro-switch wires

for continuity.

No wire feed

at gun, feeder

operating properly.

Circuit breaker in feeder/

control box open.

Check motor leads for

short. Reset.

Bad potentiometer.

Check potentiometer with

meter.

Broken electrical cable.

Check motor and

potentiometer wires for

continuity.

Wire feeds, but

welding wire is not

energized.

Loose or no cable

connections.

Check all power

connections.

Welding power source.

Check power source.

Wire feeds

erratically.

Dirty or worn conduit.

Blow out or replace

conduit.

Wrong size contact tip.

See contact tip table.

Idler roll stuck.

Check for lock washer

under idler roll, or replace

if damaged.

Wire feeds one

speed only.

Bad potentiometer.

Check with meter.

Broken electrical cable.

Check potentiometer

wires for continuity or

short.

Bad speed control.

See specific feeder/

control owner's manual for

speed control operation.

Wire walks out of

drive rolls.

Idler roll upside-down.

Place groove in idler roll

toward top.

Rear wire guide missing.

Replace wire guide.

Consult wire feeder and welding power supply owners manuals for further

problem solving solutions.

Advertising