Functional description, Motor, Extension cord selection – Porter-Cable 7414 User Manual

Page 6: Foreword

Advertising
background image

6

8.

CLEAN UP ALL REMOVED PAINT and dust by wet mopping the floors.

Use a wet cloth to clean all walls, sills and any other surfaces where paint or
dust is clinging. DO NOT SWEEP, DRY DUST OR VACUUM. Use a high
phosphate detergent or trisodium (TSP) to wash and mop areas.

9.

AT THE END OF EACH WORK SESSION put the paint chips and debris

in a double plastic bag, close it with tape or twist ties and dispose of properly.

10. REMOVE PROTECTIVE CLOTHING and work shoes in the work area to
avoid carrying dust into the rest of the dwelling. Wash work clothes
separately. Wipe shoes off with a wet rag that is then washed with the work
clothes. Wash hair and body thoroughly with soap and water.

MOTOR

Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60
cycle A.C. current and voltage within plus or minus 5 percent of that shown
on the specification plate on the tool. Several models, however, are designed
for A.C. current only. Refer to the specification plate on your tool for proper
voltage and current rating.

CAUTION: Do not operate your tool on a current on which the
voltage is not within correct limits. Do not operate tools rated A.C.
only on D.C. current. To do so may seriously damage the tool.

EXTENSION CORD SELECTION

If an extension cord is used, make sure the conductor size is large enough to
prevent excessive voltage drop which will cause loss of power and possible
motor damage. A table of recommended extension cord sizes will be found
in this section. This table is based on limiting line voltage drop to 5 volts (10
volts for 230 volts) at 150% of rated amperes.

If an extension cord is to be used outdoors it must be marked with the suffix
W-A following the cord type designation. For example – SJTW-A to indicate
it is acceptable for outdoor use.

RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS

FUNCTIONAL DESCRIPTION

FOREWORD

Your Porter-Cable Disc Sander is designed for numerous sanding and

Length of Cord in Feet

115V

25 Ft.

50 Ft.

100 Ft.

150 Ft.

200 Ft.

250 Ft.

300 Ft.

400 Ft.

500 Ft.

230V

50 Ft.

100 Ft.

200 Ft.

300 Ft.

400 Ft.

500 Ft.

600 Ft.

800 Ft. 1000 Ft.

0-2

18

18

18

16

16

14

14

12

12

2-3

18

18

16

14

14

12

12

10

10

3-4

18

18

16

14

12

12

10

10

8

4-5

18

18

14

12

12

10

10

8

8

5-6

18

16

14

12

10

10

8

8

6

6-8

18

16

12

10

10

8

6

6

6

8-10

18

14

12

10

8

8

6

6

4

10-12

16

14

10

8

8

6

6

4

4

12-14

16

12

10

8

6

6

6

4

2

14-16

16

12

10

8

6

6

4

4

2

16-18

14

12

8

8

6

4

4

2

2

18-20

14

12

8

6

6

4

4

2

2

Nameplate Ampere Rating

283800 - 07-31-00.QXD 9/23/02 1:34 PM Page 6

Advertising