FEATURE DETAILS

Protect or Disconnect™ AC Surge Protection

When the MAX

®

5300 is subjected to a high voltage surge, its voltage output is limited to a safe level and the high levels

of surge current are diverted away from the connected equipment.

• When subjected to a 6,000V (open circuit voltage) / 500A (short circuit current) surge, the MAX

®

5300 limits

its voltage output to less than 330V peak, UL’s lowest rating. The MAX

®

5300 will withstand, without

damage, multiple 12,000A surges, far exceeding the UL maximum requirement of only 3,000 Ampere surges.

• If the magnitude of the surge is greater than the capacity of the surge protection components, the MAX

®

5300’s

Protect or Disconnect™ Circuitry will disconnect your equipment in order to protect it. The MAX

®

5300

will need to be repaired or replaced by Panamax if this occurs.

SurgeGate Plus™ Protection

The MAX

®

5300 constantly monitors the AC line voltage for unsafe voltage conditions such as prolonged overvoltages

and undervoltages (brownouts). These unsafe conditions pose a very dangerous threat to all electronic equipment within
the home. If the MAX

®

5300 senses an unsafe power condition, it will automatically disconnect your equipment from

the power to protect equipment from damage. Once the voltage returns to a safe level, the MAX

®

5300 will automatically

reconnect the power.

If the line voltage exceeds the overvoltage threshold (132VAC) or falls below the undervoltage threshold (90VAC), the
MAX

®

5300 will perform the following tasks until line voltage returns to a safe level:

1. Disconnects power to all connected equipment.
2. Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition.

The MAX

®

5300 requires line voltage to return to within the safe operating range for 10 seconds before returning to normal

operating mode. This is referred to as “Over/Undervoltage Recovery”. The safe operating range is considered 5V above the
under-voltage threshold (~95V) and 5V below the overvoltage threshold (~127V). Once this safe operating range is reached,
the MAX

®

5300 will perform the following functions:

1. Unsafe Voltage LED will blink 4 times per second for Over/Undervoltage Recovery.
2. Power is restored to all connected equipment after the 10-second delay. The normal start-up sequence as

determined by the “High-Current Outlets Turn-On Switch” and “Outlet Bank 2 Turn-Off Switch” will be followed.

The MAX

®

5300 provides protection against common problems on the AC power line. This includes spikes/surges and

sustained overvoltages or undervoltages. Panamax’s exclusive Protect or Disconnect™ circuitry is designed to protect
against spikes/surges while the SurgeGate Plus™ circuitry is for sustained over/under voltage protection.

1. Voltage reaches an unsafe high

level and the SurgeGate Plus™
disconnects.

2. Voltage reaches a safe level and

SurgeGate Plus™ automatically

reconnects.

3. Voltage reaches an unsafe low level

and SurgeGate Plus™ disconnects.

4. Voltage reaches a safe level and

SurgeGate Plus™ automatically

reconnects.

1. Voltage reaches an unsafe level.

2. If surge is greater than MAX

®

5300 capacity, it disconnects.