Warning – Pentair Hydrel Fixture Housing 620001 User Manual

Page 10

Advertising
background image

P/N 620001

10

Rev. A 1-18-06

Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves
and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause
severe personal injury and/or property damage.

WARNING

1. If there is no internal bond wire as shown, skip to STEP 6.
2. If there is an internal bond wire with a non-listed potting material around the bond post, remove the potting

material completely. A non-listed potting material would be silicone, RTV, etc.
a. Be very careful not to damage the No. 8 bond wire, the screw or the post.

3. Replace the bond wire or the bonding screw if it is damaged. Then, go to instruction STEP 3 and complete the

procedures through STEP 5.

Alternate Repair Instructions

STEP 2

hn-02-11-16-98

Fixture 2.

Light Fixture
Cord

Internal Bond
Wire

Remove bonding
lug non-listed
potting material if
present, check
that screw is
tight.

Advertising