Alternate Repair Instructions

STEP 3

1. Attach No. 8 copper jumper wire to one of the two unused posts on the hub ring.

a. Place the ring over the post, and press the jumper wire in the gap between the ring and post opposite the

ring set screw.

2. Tighten the set screw firmly.

hn-07-11-16-98

Figure 3.

Post clamp
ring and set
screw

Anode

Copper
Mechanical
Lug

#10
Stainless
Screw