4. TESTING PROCEDURE

3. Boiling control lever adjustment

Such a mechanical operation as center thermostat goes up and down is used to turn on

and off the micro-switch. Check and adjust this relationship as shown below.

When the boiling switch is turned on. When the boiling switch is turned off.

Checking

The auxiliary lever presses the push-

button (The “WARM” lamp comes on.)

The auxiliary lever does not press

the push-button (The “COOK” lamp

comes on.)

Adjusting

To gain the above relationship, adjust the auxiliary lever by bending it with

long nose pliers.