Function of center thermostat and thermalfuse – Panasonic SR-GA721 User Manual

Page 6

Advertising
background image

6

SR-GA421/SR-GA281/SR-GA721

C. Thermal Fuse

The thermal fuse is used to open the circuit to the cooking heater when the temperature has

gone unusually high. This happens in cases such as incomplete contact between the heater

and pan or if the switch buttons is forced to stay on keeping the heater energized abnormally.

This fuse is not a resetting device and must be replaced after openning.

Whenever replacing the fuse make sure the protective cover is placed over all exposed wiring.

Cause of Fusion

[A] Improper contract between heater and pan

2. FUNCTION OF CENTER THERMOSTAT AND THERMALFUSE

[B] Forced application of current

Cause

Pan collar or deformed

Foreign matter adhering

Body dented or deformed Pan bottom dented or

deformed

Heater surface deformed

or corroded

Remedy

Remove foreign matter

by of (-) screw-driver,

etc., and then polish with

= 320 water paper while

wetting it with water.

Repair or replace body.

Replace pan.

Replace cooking heater.

Cause

Chopstick, wooden

piece, etc. inserted onto

cooking button. (continu-

ous application of current)

Switch lever deformed

or maladjusted, causing

continuous application of

current.

Remedy

Inserted to prevent ear-

lier turning off? Refer to

cause in (a) above.

Repair or replace parts.

When fusion takes place, check the cause, set right the faulty section, and be sure to use

replacement parts.

Advertising