3.0 Operating the Boiler

7

3.2

Temperature Control

1. Central Heating: The central heating hot water flow

temperature can be adjusted between 30° C (± 5° C)

minimum and 85° C (± 5° C) maximum.

2. Turn the control knob clockwise to increase the

temperature (Fig. 9).

3. In normal winter usage we recommend that the

central heating temperature be set at maximum.

4. Domestic Hot Water Pre-Heat: To enjoy optimum

performance of the boiler the pre-heat control should

be set fully clockwise to the ON position (Fig. 10).

When there is a demand for hot water it will be supplied

at approximately 65° C instantaneously.

5. Turning the control 15° clockwise from the OFF

position will activate the pre-heat feature. Hot water will

be supplied at approximately 35° C instantaneously.

6. To increase the temperature turn the control further

clockwise. For example, when set 90° clockwise the

boiler will supply hot water at approximately 44° C

instantaneously. At a position 180° from clockwise (i.e.

straight down) the hot water will be supplied at 52° C

instantaneously.

7. When the control is set anywhere between 15°

clockwise from the OFF position and the ON position,

the pre-heat feature will operate.

8. With the control in the OFF position (Fig. 11) the pre-

heat feature will not operate. Hot water will be supplied

at approximately 50° C.

9. The pre-heat feature will function with the selector

switch in either operating position. This is indicated by

the domestic hot water mode neon flashing (Fig. 12).

10. The flow rate can be reduced down to as low as 2.5

litre/min. The boiler will still recognise the need to heat

the water.

3.3

Flame Failure Reset

1. The red flame failure neon ( ) will illuminate in the

event of the burner failing to light, when incomplete

lighting of the burner occurs or blockage of the

condensate drain (Fig. 12).

2. Turn the selector switch fully anti-clockwise against

the spring pressure to the ‘Reset’ position for at least

two seconds and release (Fig. 13). Set the selector to the

required position to light the boiler.

3. If the flame failure light illuminates repeatedly a fault is

indicated with either the boiler, the gas supply or the

condensate drain. Your Installer or Service Engineer

should be called as soon as possible.

OFF

ON

PREHEAT

Reset

Domestic Hot Water

Pre-Heat Control

ON Position

Fig. 9

Central Heating

Temperature Control

Fig. 10

Reset Position

Fig. 13

30

o

40

o

50

o

60

o

70

o

80

o

Flame Failure
Neon

Fig. 12

OFF

ON

PREHEAT

Fig. 11

Domestic Hot Water

Pre-Heat Control

OFF Position

Domestic Hot
Water Neon