3.0 Operating the Boiler

9

3.9

Central Heating System Pressure

1. The water pressure in the central heating system is

indicated by the pressure gauge.

2. With the system cold and the boiler not operating

the pressure should be between 0.5 and 1.0 bar. During

operation the pressure should not exceed 2.5 bar, and

will normally be between 1.0 and 2.0 (Figs. 18 & 19).

3. A pressure of 3 or greater indicates a fault. The safety

pressure relief valve will operate, at a pressure of 3

(Fig. 20). It is important that your Installer or Service

Engineer is contacted as soon as possible.

4. The MINIMUM pressure for correct operation is 0.5.

If the pressure falls below 0.5, this may indicate a leak

on the central heating system (Fig. 21).

3.10

To Shut Off the Boiler

1. For short periods: Turn the selector switch to the

OFF position (Fig. 22).

2. For long periods: Turn off the selector switch

(Fig. 22), electricity and gas supplies.

If your home is to be left unoccupied for long

periods during cold weather the boiler and whole

system should be drained unless there is additional

frost protection.

3. Your installer will advise you about frost protection

and draining the system.

IMPORTANT: When the selector switch is in the
‘0’ (Off) position the electrical supply to the boiler
is isolated. The boiler will not operate and the
integral timer (if fitted) will require resetting once
the selector switch is set to either Position (i) or
Position (ii).

3.11

Frost Protection Mode

1. The frost protection feature will operate when the

selector switch is in the central heating and domestic

hot water mode.

The gas and electrical supplies to the boiler must be on

and the system pressure must be within the range

described in Section 3.9.

2. If the system temperature falls below 5°C, then the

boiler will fire until the water temperature has been

raised.

3. Further frost protection can be incorporated by using

a frost thermostat to protect the whole system.

2

1

0

4

3

bar

2

1

0

4

3

bar

2

1

0

4

3

bar

2

1

0

4

3

bar

ON/OFF

Selector Switch

Reset

OFF Position

Fig. 22

Normal Pressure (when cold)

Normal Pressure (operating)

Fig. 18

Fault

Fig. 19

Below Minimum

Fig. 20

Fig. 21

Pressure Gauge