Other controls – PSC PT2000 User Manual

Page 100

Advertising
background image

Programming Parameters

90

PT2000™ & TopGun™

Other Controls

Enter 1 for On and 0 for Off.

Enable manual reset

B0

On/Off

On or Off

On

On

On

Auto-Off

B2

Value

00–99

(minutes)

00

60

10

Intercharacter delay (keyboard
wedge only)

B3

Value

00–99

(milliseconds)

00

06

00

Add symbology identifiers

*

B5

On/Off

On or Off

Off

On

Off

Good-read tone

B8

Value

00 (low) – 07 (high)

05

05

05

Good-read number of beeps

B9

Value

01–04

01

01

01

Good-read tone duration

BA

Value

00 = 0.14 sec.
01 = 0.07 sec.
02 = 0.45 sec.
03 = 0.22 sec.

01

01

01

Beeper volume

BC

Value

00 = Off

01 (low) – 07 (high)

08 = One level higher

09 = One level lower

07

07

07

Error tone

BD

Value

00 (low) – 07 (high)

03

03

03

Time format

D8

On/Off

On = 24-hour
Off = 12-hour

On

On

On

Date format

D9

On/Off

On = International

Off = U.S.

Off

Off

Off

Keyboard click

DD

On/Off

On or Off

On

On

On

Laser delay

DE

Value

00–99

(10-millisecond units)

01

01

01

*

A

= UPC-A

E

= UPC-E

K

= Code 128

B

= Interleaved 2 of 5

G

= EAN-8

L

= Code 93

C

= Code 39

I

= Codabar

M

= EAN-13

*.

Code Parameter

ID #

Type

Acceptable Input

Predefined Defaults

D0

D1

D2

PT2000.book Page 90 Thursday, February 26, 2004 9:34 AM

Advertising
This manual is related to the following products: