ENVIRONMENTAL RANGE

The operating temperature ranges from a minimum of -50

°

F (-45

°

C) to a maximum of 122

°

F (50

°

C) for sustained system operation or

140

°

F (60

°

C) absolute maximum. The entire unit can de-ice and be operational in two hours from a temperature of -13

°

F (-25

°

C). The

thermostatically controlled heater consumes 10 watts and cycles on at 70

°

F (21

°

C) and off at 85

°

F (29

°

C), while the window defroster

runs continuously and consumes 2.5 watts.

PAN AND TILT FUNCTIONS

Controller

Pan

Tilt

Type

(Capability – 360

°

Continuous Pan Rotation)**

(Viewing Range – +33

°

to -83

°

)***

Fixed speed

Speed determined by controller

Speed determined by controller

*Variable speed

0.1 to 40

°

per second, depending on joystick and

0.1 to 20

°

per second, depending on joystick and zoom

zoom positions

positions

*Turbo Mode

100

°

per second

Does not affect the tilt speed

*Preset Mode

100

°

per second

30

°

per second

* 50 mph wind-speed profile.

** If manual limit stops are set, “Pan Limit” appears on your monitor when a limit stop is reached (except when you are programming or

running a pattern). This does not apply to scan limit stops.

*** When the system reaches the upper limit, “Tilt Limit” appears on your monitor (except when you are programming or running a

pattern).

If the proportional pan mode is enabled (refer to the

Proportional Pan in the Programming section), the pan and tilt speeds will depend on

the amount of zoom. At telephoto zoom settings, the pan and tilt speeds will be slower for a given amount of joystick deflection than at
wide zoom settings. This keeps the image from moving too fast on the monitor when there is a large amount of zoom. This slowing does
not happen when going to a preset but does occur in turbo mode when high zoom is selected. The minimum pan and tilt speeds are 0.1
degree per second at full zoom.

SCAN SPEED

Scan speed is adjustable from 1 to 40 degrees per second through the programming menu.

PRESET FUNCTIONS

The Esprit

®

system is capable of going to 64 preset locations, each with a 20-character label. The presets are numbered 1-32 and 35-66.

Refer to the documentation for your control system for programming presets.

If you command the pan and tilt to go to an undefined preset, erratic operation may result.

Presets 33 and 34 are fixed commands, meaning that you cannot program them. Preset 33 is the “flip” command, which will pan the
system 180 degrees. Preset 34 is the “pan zero” command, which will pan the system to the factory-determined zero reference point.

RANDOM, FRAME, AND AUTO SCANNING

Select preset 97 (30) to start random scanning. Select preset 98 (31) to activate frame scanning (three seconds of scanning followed by a
three-second pause). Select preset 99 (32) to start auto (continuous) scanning. Scan limit stops are controlled by software. Refer to the
Limit Stops section to program the scan limit stops.

When the pan and tilt reaches a scan limit stop, it reverses direction. Select preset 96 (29) to stop a scan. Any pan and tilt or lens
command also will stop a scan.

ZONES

A zone is a programmed pan area with set boundaries and identifying label. The Esprit system has a maximum of eight zones, each with a
20-character label. Zones can be programmed to blank video when the camera pans into the zone area. If a zone is blanked, the system
displays the message, VIDEO BLANK. (Refer to

Zone Blank in the Programming section for instructions.)