15 - ENG

1000003754

wise).

7. Replace hose and new hose clamp.
8. Perform the Break-in Procedure. See "Break-in Procedure" in the Operation

section.

TO REPLACE REGULATOR

1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance

section.

2. Unplug

unit.

3. Using an adjustable wrench remove

Safety
Valve

Regulator
Manifold

Gauges

Quick Connect

the gauges, quick connect, and
safety valve from the regulator
manifold.

4. Remove the hose by removing the

hose clamp. NOTE: The hose clamp
is not reusable. You must purchase a
new hose clamp, see the Parts List
Manual or purchase a standard hose
clamp at a local hardware store.

5. Remove pump mounting screws securing pump (one on each side).

6. Carefully slide pump from brackets and out of the way.

7. Using an adjustable wrench remove the regulator manifold.

8. Apply pipe sealant to new regulator manifold and assemble, tighten with

wrench.

9. Reapply pipe sealant to gauges, quick connect, and safety valve.

10. Reassemble all components in reverse order of removal. Make sure to orient

gauges to read correctly and use wrenches to tighten all components.

Regulator
Manifold

Hose

Clamp

Pump Mounting Screw

Regulator
Manifold

Pump shown
moved out of
the way