Control panel – Panasonic EY7411 User Manual

Page 8

Advertising
background image

- 8 -

Reference for Adjusting Torque

Setting

Torque

Use

1

Approx: 0.9 N·m

(3.0 kgf-cm or .6 in-lbs)

For driving

screws

5

Approx: 0.8 N·m

(8.4 kgf-cm or 7.3 in-lbs)

9

Approx: 1.35 N·m

(13.8 kgf-cm or 1.0 in-lbs)

13

Approx: 1.88 N·m

(19. kgf-cm or 16.6 in-lbs)

17

Approx: .41 N·m

(4.6 kgf-cm or 1.3 in-lbs)

1

Approx: .94 N·m

(30.0 kgf-cm or 6.0 in-lbs)

Approx: 4.4 N·m

(45.0 kgf-cm or 39.0 in-lbs)

For power-

ful driving

screws and

drilling

● When using at high speeds, set the

clutch at 10 or below. (Operation

stops at the maximum torque of 1.5

N·m (15 kgf-cm) when the scale is

higher.)

● The auto shut-off function may

become inoperable at high clutch

settings when battery power drops.

Recharge the battery in that case.

NOTE:

The chart is only a reference. The

torque settings may differ by materi-

als, types of screws, etc. Please test

it at your own conditions before use.

Control Panel

Manufacturer settings upon shipment

Count system: Count down system

Count setting value: 99

Buzzer sound pitch: b1 (Low sound)

Double tightening counting preven-

tion count time: 0 (OFF)

Hold switch: Released

Please set the settings according to

conditions of use.

Screw count function

● Counts the number of auto stops.

(Counts the number of screws driven)

● The count method can be selected

from “UP” or “DOWN”.

● When the set number of screws to be

driven is reached, a buzzer sounds

and the count value is reset.

● The buzzer sound can be selected

from 3 types of sound.

● Double tightening counting prevention

function

Work (double tightening and screw

driving confirmation, etc.) that began

within the set time is not counted after

the driven screws are counted.

Count display lamp

Count system display

lamp

Lock button

Switch

Hold switch

ON

Release

Starting the control panel

1. Release the hold switch.
. To illuminate the control panel

1

Release the lock button

2

Press (Control panel is lit.)

● The count display lamp and “UP” or

“DOWN” are illuminated.

Setting the count functions (Screw

count setting/Count system setting)

1. Press while the control panel is

illuminated.

Each time is pressed, the screw

count setting and count system set-

ting switch flash.

● Screw count setting

→ Count display lamp flashes.

● Count system setting

→ “UP” or “DOWN” flashes.

. Screw count setting
Set the number of screws with

or

.

● The range can be set within 0 – 99.

● 0 is not counted.

EY7411(UL).indb 8

2007/02/05 14:56:37

Advertising