Panasonic EY7411 User Manual

Page 9

Advertising
background image

- 9 -

Count system setting

Press . “UP” or “DOWN” will begin

to flash. Next select

(“UP”) or

(“DOWN”).
● Press and hold the ( ) or ( ) but-

tons to vary the value continuously.

< Count System “UP” >

● Displays the count for the number

of screws driven.

(

Set number )

The settings are activated by pushing

.

● When the set number of screws is

reached, the buzzer sounds and

the count value resets to zero.

< Count System “DOWN” >

● Displays the count for the remain-

ing number of screws to be driven.

( Set number

)

● When the set number of screws to

be driven is reached, the buzzer

sounds and the count value resets

to original set number.

3. The settings are activated by pushing

.

● The previous setting will be can-

celled and replaced with the new

setting.

4. To prevent changes in the set values

due to operational errors.

ON

● Turn the HOLD switch

to ON.

Convenient function settings (buzzer

sound setting/double tightening

counting prevention time setting)

Buzzer sound setting

1. Press for  or more seconds while

the control panel is illuminated.

● Count display lamp “F1” is illumi-

nated.

. The buzzer sound can be selected

with when “F1” is illuminated.

Operation

Display

Sound Frequency

b3

High pitched sound

(Approx. 4 kHz)

b

Medium pitched

sound (Approx. 3

kHz)

b1

Low pitched sound

(Approx.  kHz)

b0

No sound (OFF)

● If is pressed while in the buzzer

mode, the buzzer sound saved

from the previous setting is dis-

played.

3. The settings are activated by pushing

.

4. To prevent changes in the set values

due to operational errors.

ON

● Turn the HOLD switch

to ON.

Double tightening counting preven-

tion time setting

1. Press for  or more seconds while

the control panel is illuminated.

● Count display lamp “F1” is illumi-

nated.

. Press again to illuminate “F” and

select the time with .

Operation Display No. of

seconds

Following the

screw count,

screw driving

within the set

number of

seconds is

not counted.

30

3

seconds

1

0.1

second

0

OFF

● If is pressed while in the time

mode, the time setting saved from

the previous setting is displayed.

3. The settings are activated by pressing

.

4. To prevent changes in the set values

due to operational errors.

ON

● Turn the HOLD switch

to ON.

To change the screw count while in

use

1. Release the hold switch.
. Adjust the count value with .

● The displayed number of screws

EY7411(UL).indb 9

2007/02/05 14:56:39