End-to-end maintenance checklist – Paradyne BitStorm IP DSLAM 1900 User Manual

Page 122

Advertising
background image

3. BitStorm 1900 Maintenance

3-106

BitStorm 1900 Installation and Maintenance Guide

1900-A2-GN20-00

End-to-End Maintenance Checklist

Table 3-2: End-to-End Maintenance Checklist

Problem

Check

No voice or data service

• Verify power at all points in the system

• Verify connections and wiring conditions at all

points

Voice but no data service

• Verify that there is not an external network problem

such as a server being down

• Verify that the Ethernet card on the PC connected

to the modem has been configured

• Verify that the correct type of Ethernet cable

(“straight” or “crossover”) is being used for the
application.

• Verify that the green LEDs at the various Ethernet

connection points are lit

• Check for 10Base-T cable damage

• Verify router configuration and installation

• See the checklist in Table 3-1, “Voice/Data

Connectivity Maintenance in Facility Room,” on
page 105
.

Data but no voice service

• Check dialtone at the PSTN/PBX cross-connect to

verify that there is not an external voice network
problem

• Check/replace filter card in filter shelf

Advertising