13) Position and lock the ice chute onto the front and rear frame pipes by pushing the ice

chute down until it clicks onto both frame pipes. See Fig. 36.

14) Slide in the water tank along the rails at the bottom of the left and right brackets until it

locks into place. See Fig. 37.

Right Bracket

Rail

Rail

Fig. 34

Fig. 35

Fig. 36

Fig. 37

7) Disconnect the discharge tube from the spray assembly, then slide out the spray

assembly. See Fig. 32.

8) Remove the two caps. See Fig. 33.

Discharge Tube

Spray Assembly

Caps

9) Soak all of the removed parts and the scoop in the sanitizing solution for 10 minutes. If

the spray assembly nozzles are clogged, clean them with a wire or a suitable brush.

10) Rinse the parts thoroughly with clean water.
11) Refit the 2 caps in their correct positions. Make sure the reducing pipe is in place in the

center. See Fig. 34.

12) Slide in the spray assembly along the rails on the left and right brackets. See Fig. 35.

Connect the discharge tube securely to the spray assembly; a loose fitting may cause a
water leak.

Fig. 32

Fig. 33

Left Bracket

Right Bracket

Left Bracket

Caps

Discharge Tube

Ice Chute

Front Frame

Pipe

Rear Frame

Pipe

Water Tank