3. Sanitizing Solution

IMPORTANT

For safety and maximum effectiveness, use the solution immediately after
dilution.

Dilute 0.5 fl. oz. (14.8 ml or 1 tbs) of a 5.25% sodium hypochlorite solution (chlorine
bleach) with 1 gallon (3.8 l) of warm water. This is a minimum amount. Make more
solution if necessary. Using a chlorine test strip or other method, confirm that you have a
concentration of about 200 ppm.

4. Sanitizing Procedure

1) Make sure the control switch is in the "OFF" position and the storage bin is empty.
2) Remove the slope from the storage bin by carefully bending it in the center and

releasing it from the 2 slope shafts. See Fig. 28.

3) Remove each separator by lifting it to the horizontal position and pushing it hard inward.

See Fig. 29.

4) Disconnect the suction tube. Allow the water tank to drain.
5) Spread out the tabs to unlock the water tank, then slide it out. See Fig. 30.
6) Lift off the ice chute from the front frame pipe and then from the rear frame pipe. See

Fig. 31.

Separator

Ice Chute

Front Frame Pipe

Tab

Tab

Slope

Fig. 28

Fig. 29

Fig. 30

Fig. 31

Rear Frame Pipe

Slope Shafts

Water Tank