2 configuring dip switch s1, 0 operation, 1 power up – Patton electronic 2173 User Manual

Page 14: Configuring dip switch s1, Operation, Power up

Advertising
background image

14

4.2 CONFIGURING DIP SWITCH S1

DIP switch S1 is where you configure the CopperLINK line. The following
tables describe the configuration for the 2173.

S1-2: Impulse Noise Protection

Fast Mode:

Direct data transmission with latency less than 1ms

Interleave Mode:

Provides data transmission protection for up to 250

ms impulse noise with latency less than 6 ms

S1-3: Rate Limit

S1-4: General Protection (Signal to Noise Ratio)

6dB:

Original line noise protection with 6dB SNR

9dB:

Better line noise protection with SNR up to 9dB

5.0 OPERATION

Once the Model 2173s are properly installed, they should operate trans-
parently. No user settings required. This section describes reading the
LED status monitors.

5.1 POWER UP

Before applying power to the Model 2173, please review section 3.3,
“Connecting Power” on page 12
to verify that the unit is connected to the
appropriate power source.

Table 1:

2173 Firmware Configuration

Position

S1-1

S1-2

S1-3

S1-4

Master/

Slave

Mode

Rate

SNR

ON

Slave

(CPE)

Fast

Auto

6dB

OFF

Master

(CO)

Interleave

25/25

9dB

S1-3

Rate

OFF

25/25

ON

Auto