APPENDIX A

SPECIFICATIONS

A.1 LAN CONNECTION

• Two shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet

• CopperLINK Connection:

Shielded RJ-45

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair.

A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE

• Line Rate: Up to 155 Mbps aggregate (upstream/downstream) via

Auto Rate; and 25/25 Mbps via DIP switch settings.

• Distance: Up to 5,500 ft (1.6 km)

Note

Distances depend on line rate and line conditions.

A.4 LED STATUS INDICATORS

• Power (Green)

• CopperLINK: Link (Green)

• Ethernet: Link (Green) & Activity (Flashing Green)

• Remote (Green)

• Local (Green)

A.5 POWER SUPPLY

External AC and DC options:

• AC: 120 VAC, 220 VAC, and UI (120–240 VAC)

• DC: 12 VDC, 24 VDC and 48 VDC

• Power consumption: 860mA at 5V

A.6 TEMPERATURE RANGE

0–40°C

A.7 HUMIDITY

Up to 90% non-condensing.

A.8 DIMENSIONS

1.58H x 4.16W x 3.75D in. (10.6H x 4.1W x 8.8D cm)