Major Operating Controls and Their Functions

_

Front Panel

5

Cooling Fan
• Do not block or obstruct the ventilation during operation. It may otherwise cause

internal heating or fire.

• The life of this fan is approximately 50,000 hours (at room temp. 25°C). Replace the

fan as needed.
(When the room temperature is higher than 35°C, replace the fan earlier.)
Be sure to ask the dealer for the replacement.

_

Top and Bottom Panels

Pin No.

1
2
3
4
5
6

Signal

Return control
VTR-S/S
UNREG GND
Iris manual selection
Iris control
UNREG 12V

Pin No.

7
8
9

10
11
12

Signal

Iris follow
Iris auto selection
——
——
——
NC

1

Lens Mount
2/3q standard bayonet type (B4 mount) lens is installed.

2

Lens Fixing Ring Knob
Lens is fixed by turning the knob counterclockwise.

3

Cable Clamp
Used to clamp the lens cable.

4

Lens Connector [LENS]
Used to connect the camera cables of the lens.