Patton electronic 3088 User Manual

Page 37

Advertising
background image

37

If 3088 (Far End) already has an active remote console session

open, you will see the message

Console: Remote console con-

nection request rejected. This can also happen if the remote
3088 (far-end) has an established remote console session with
the local 3088 (near-end) which has timed out.

6. Enter the password at the password prompt for the remote

console session.

Note

The passwords for a local console session of the 3088 (near-

end) and the remote console session of the 3088 (far-end)
should be different for the purpose of security.

7. You should now be logged into the remote 3088(far-end) via the

remote console session. The communication with the remote 3088
(far-end) is essentially the same as having a local
console connection.

Note

The local or remote 3088 may be CO or CPE, as long as there

is one of each. Either the CO or CPE unit may accept a remote
console connection.

Note

With a remote console session open, a user at PC (far-end) is

blocked from using the local console. Upon typing anything, the
3088 (far-end) sends a message to the PC (far-end) stating
“Console: Remote console connection is open.”