How to use your unit – Porter-Cable C6110 User Manual

Page 12

Advertising
background image

12- eNG

Drain Valve: The drain valve is located at the base of the

Drain

Valve

air tank and is used to drain condensation at the end of

each use.
Check Valve: When the air compressor is operating, the

check valve is "open", allowing compressed air to enter

the air tank. When the air compressor reaches "cut­out" pressure, the check

valve "closes", allowing air pressure to remain inside the air tank.
Pressure Release Valve: The pressure release

Check

Valve

Pressure

Release

Valve

valve located on the side of the pressure switch, is

designed to automatically release compressed air

from the compressor head and the outlet tube when

the air compressor reaches "cut-out" pressure or is

shut off. The pressure release valve allows the

motor to restart freely. When the motor stops

running, air will be heard escaping from this valve

for a few seconds. No air should be heard leaking

when the motor is running or after the unit reaches

"cut-out" pressure.
Motor Overload Protector (not shown): The motor

has an automatic reset thermal overload protector. If the motor overheats for

any reason, the overload protector will shut off the motor. The motor must

be allowed to cool down before restarting. The compressor will automatically

restart after the motor cools.
Air Intake Filter (not shown): This filter is designed to clean air coming into the

pump. This filter must always be clean and ventilation openings free from obstruc-

tions. See Maintenance.

HOW TO USE YOUR UNIT

How to Stop
Set the auto/off switch to "off".
Before Starting

Do not operate this unit until you read this instruction manual

for safety, operation and maintenance instructions.

Before Each Start-Up
1. Set the auto/off switch to "off".
2. Plug the power cord into the correct branch circuit receptacle. (Refer to

Voltage

and Circuit Protection paragraph in the Installation section of this manual.)

3. Pull the regulator knob out and turn counterclockwise to set the outlet pressure

to zero.

4. attach hose and accessories.

Risk of unsafe operation. Firmly grasp air hose in hand when

installing or disconnecting to prevent hose whip.

Risk of unsafe operation. Do not use damaged or worn

accessories.
NOTE:
The hose or accessory will require a quick connect plug if the air outlet is

equipped with a quick connect socket.

Advertising