19 - eNG

PROBLEM

CAUSE

CORRECTION

Motor will

not run

Motor overload protection

switch has tripped.

Refer to

Motor Overload Protection

under Operation. If motor overload

protection trips frequently, contact

a Trained Service Technician

Tank pressure exceeds

pressure switch

"cut-in" pressure.

Motor will start automatically when

tank pressure drops below "cut-

in" pressure of pressure switch.

Check valve stuck open. Remove and clean, or replace.

loose electrical

connections.

Check wiring connection inside

pressure switch and terminal box area.

Possible defective motor

or starting capacitor.

Have checked by a Trained

Service Technician.

Paint spray on internal

motor parts.

Have checked by a Trained Service

Technician. Do not operate the

compressor in the paint spray area.

See flammable vapor warning.

Pressure release valve on

pressure switch has not

unloaded head pressure.

bleed the line by pushing the

lever on the pressure switch to

the "off" position; if the valve

does not open, replace switch.

Fuse blown, circuit

breaker tripped.

1. Check fuse box for blown fuse

and replace as necessary. Reset

circuit breaker. Do not use a fuse

or circuit breaker with higher

rating than that specified for

your particular branch circuit.

2. Check for proper fuse. You

should use a time delay fuse.

3. Check for low voltage conditions

and/or proper extension cord.

4. Disconnect the other electrical

appliances from circuit or

operate the compressor on

its own branch circuit.

Knocking Noise Possible defect in

safety valve.

operate safety valve manually

by pulling on ring. If valve still

leaks, it should be replaced.

Defective check valve.

Remove and clean, or replace.

LIMITED WARRANTY

PoRTeR-Cable industrial tools are warranted from date of purchase, as follows:

3 YEAR – limited warranty on 2-stage oil-free air compressor pumps

operating at 1725 RPM.

2 YEAR – limited warranty on oil-lubricated air compressor pumps.

1 YEAR – limited warranty on all other air compressor components.

PoRTeR-Cable will repair or replace, without charge, at PoRTeR-Cable’s option,

any defects due to faulty materials or workmanship. For further detail of warranty

coverage and warranty repair information, call 1-(888)-848-5175 or visit deltaport-

ercable.com. This warranty does not apply to accessories or damage caused

where repairs have been made or attempted by others. This warranty also does

not apply to merchandise sold by PoRTeR-Cable which has been manufactured

by and identified as the product of another company, such as gasoline engines.

Advertising