Network menu, English, E-mail setup page – Panasonic PT-DW90XE User Manual

Page 102

Advertising
background image

NETWORK menu

102

- ENGLISH

Settings

E-mail setup page

J

With this projector, if a problem occurs or if the lamp usage time reaches a set value, an e-mail message can

be sent to one or more preset e-mail addresses (maximum two addresses).

Click [Detailed set up], then [E-mail set up] to display the E-mail setup page.

Select “Enable” to use the E-mail function.

Enter the IP address or server name of the E-mail

server (SMTP). The DNS server must be set if

the server name is entered.

Enter the E-mail address of the projector.

(maximum 63 characters)

The user can enter the location of, for example,

the installed projector so that the recipient

may easily identify the originator of the E-mail.

(maximum 63 characters)

The user can modify the minimum time interval

of temperature warning mail. The default value

is 60 minutes. In this case, the user cannot

send another mail for 60 minutes after sending

previous temperature warning mail even the set

warning temperature is reached again.

Enter the E-mail address of your desired

recipient.

Select the conditions for sending E-mail.

MAIL CONTENTS:

Select [NORMAL] or [SIMPLE].

ERROR:

an error is detected by self-diagnosis.

LAMP1 RUNTIME:

remaining lamp service time has reached the value set in the field.

LAMP2 RUNTIME:

remaining lamp service time has reached the value set in the field.

FILTER REMAIN:

remaining filter service time has reached the value set in the field.

INPUT AIR TEMPERATURE: intake air temperature has reached the value set in the field.

Advertising