W415-0442 / A / 12.13.04

11

An acceptable 61½" x 20" non-combustible (ie: brick, stone
or ceramic tile) hearth extension must be installed.
Hearth must extend 20" in front of the faceplate when it is
not elevated (see local building codes).
Hearth must extend a minimum of 6" to both sides of the
unit (61 ½").
Hearth must be a minimum of 1" thick cement board (or
equivalent) plus ¼" ceramic tile.

Ensure that the gap
between the
fireplace and a
combustible hearth
extension is sealed
with sand/cement
grout or covered
with a metal strip (or
both) to prevent
sparks and embers
from falling into this
area.

HEARTH EXTENSION

Elevated hearths must be constructed of non-combus-

Elevated hearths must be constructed of non-combus-

Elevated hearths must be constructed of non-combus-

Elevated hearths must be constructed of non-combus-

Elevated hearths must be constructed of non-combus-
tib

tib

tib

tib

tible ma

le ma

le ma

le ma

le materials suc

terials suc

terials suc

terials suc

terials such as cement b

h as cement b

h as cement b

h as cement b

h as cement bloc

loc

loc

loc

lock

k

k

k

ks or bric

s or bric

s or bric

s or bric

s or brick

k

k

k

ks

s

s

s

s.....

While the fireplace can be installed directly on the floor, a
non-combustible hearth extension is required in front of
the fireplace, that must not be built higher than the bottom
of the fireplace faceplate. It may therefore be advisable to
build the fireplace on a raised platform.
Hearths raised minimum 6 ½" must extend a minimum of
18".
A raised hearth together with the fireplace built on a raised
platform is recommended for easier wood loading and fire
viewing.

See hearth

examples.