Napoleon Fireplaces NZ6000 User Manual

Page 21

Advertising
background image

W415-0442 / A / 12.13.04

21

6. Insert the filter into the grill. Foam gasket (

1

/

2

” weather

stripping) between the grill and blower housing is recom-
mended, but not supplied.

The blower filter is washable.

7. The bottom lip of the grill latches over the bottom lip of
the housing. Use two screws to secure the top of the grill to
the facing.

b) Removing the junction box cover on the unit exposes 4
black, labeled wires:

-2 wires marked by-pass - go to
by-pass (summer) switch (not
supplied)

(overides the thermally activated
switch).

Marrett by-pass (summer)

switch wire leads se

se

se

se

separ

par

par

par

para

a

a

a

ately

tely

tely

tely

tely,,,,, if

not being used.

-1 marked blower - connects to KB-35

(rheostat)(not supplied) and then to white blower wire.

-1 marked L1 - connects to power (hot lead).

Removing the junction box cover on
the blower exposes 3 coloured
wires:

-1 black wire - goes to power L2
(neutral lead).

-1 green wire - connects to
ground.

-1 white wire - connects to KB-
35 (rheostat)(not supplied) which connects to “blower “wire.

5. Connect the 6” liner to the unit and blower collars. Se-
cure using 3 screws on each end and seal with caulking.

Liner supplied stretches to a maximum of 10’.

Liner supplied stretches to a maximum of 10’.

Liner supplied stretches to a maximum of 10’.

Liner supplied stretches to a maximum of 10’.

Liner supplied stretches to a maximum of 10’.

NZ150-KT KIT

The circulation inlet must terminate outside of the fireplace
enclosure to ensure proper air flow around the firebox.

The 6" circulation air inlet may be connected to either the
NZ64 blower kit or the NZ150-KT kit.

Avoid terminating higher than the bottom of the doors on
the unit to prevent air flow reversal.

An optional opening is covered on the other side of the
unit. If this location is preferred, switch the cover plate and
collar.