Table 360 ntak09 switch settings – Nortel Networks Circuit Card 311 User Manual

Page 876

Advertising
background image

876

NTAK09 1.5 Mb DTI/PRI card

extend from the card to the DSX-1 or LD-1. Equalizers are switch selectable
through dip-switches. The settings are shown in

Table 360 "NTAK09 switch

settings" (page 876)

.

Table 360
NTAK09 switch settings

Switch Setting

Distance to Digital Cross-Connect

1

DCH F/W

2

(LEN 0)

3

(LEN 1)

4

(LEN 2)

0 - 133 feet

Off

Off

Off

On

133 - 266 feet

Off

On

On

Off

266 - 399 feet

Off

Off

On

Off

399 - 533 feet

Off

On

Off

Off

533 - 655 feet

Off

Off

Off

Off

Receiver

The receiver extracts data and clock from an incoming data stream and
outputs clock and synchronized data. At worst case DSX-1 signal levels, the
line receiver operates correctly with up to 655 feet of ABAM cable between
the card and the external DS1 signal source.

The receiver extracts data and clock from an incoming data stream and
outputs clock and synchronized data. At worst case DSX-1 signal levels, the
line receiver operates correctly with up to 655 feet of ABAM cable between
the card and the external DS1 signal source.

The receiver extracts data and clock from an incoming data stream and
outputs clock and synchronized data. At worst case DSX-1 signal levels, the
line receiver operates correctly with up to 655 feet of ABAM cable between
the card and the external DS1 signal source.

Connector pinout

The connection to the external digital carrier is through a 15-position male
D-type connector. See

Table 361 "DS-1 line interface pinout for NTBK04

cable" (page 876)

.

Table 361
DS-1 line interface pinout for NTBK04 cable

From 50-pin MDF

connector

To DB-15

Signal name

Description

pin 48

pin 1

T

transmit tip to network

pin 23

pin 9

R

transmit ring to network

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising