Central Station Receiver 1 Format

From the table below, enter the central station's receiver format. Use number
buttons

1

through

9

. NOTE: Press

G0

for a zero and

0

for a blank space (•). Press

G 1

through

G 4

for letters B–E,

respectively. Press

J

to save. Press NEXT (

E

) button to proceed.

NOTE: Central Station Receiver 2 and 3 Formats can only be entered in
Direct Address Programming. See CS Receiver Options.

Enter User Codes

For default program, enter up to 32 User Codes, with Area 1 and Area 2
Options.Press the (

A

) button once to set the cursor to the User Code.

Use the number buttons

0

through

9

to enter the User Number,

followed by a User Code of up to 6 digits. Enter

G0

for a blank.

NOTE: If “Enable Global Ambush Code”(Address 0720) is enabled and
“Global Ambush Code” (Address 1054) is left blank(•), do not program the first
two digits of ANY User Code as '99'.

Press

J

to save. To proceed to the next User Code, press the

A

button to set the cursor to the User Number and

change it using the number buttons.

If the programmed code was less than 6 digits, enter blanks

G0 for the remaining digits.

(Direct Entry)

13

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

INTERIOR

BYPASS

SYS TBL

CHIME

FIRE/TBL

Example: Program a code of “2222” for user 02, with area 1 options of “Arm/Disarm” and “User Program”:

Enter

02 for the user number, 2222 G0 G0 for a user code,

G09 “(blank) 9” for area 1 options and G0G0 “(blank) (blank)” for area 2 options.

CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above

and press

J

to save. Similarly, to cancel a code, blank out each number of the code press

J

to save.

(

Direct Entry)

14

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

INTERIOR

BYPASS

SYS TBL

CHIME

FIRE/TBL

DATA

ENTRY

CS RECEIVER 1 FORMAT

•(blank)

Ademco Slow, Silent Knight Slow

2

Radionics Fast

3

Silent Knight Fast

4

Radionics, CD, Franklin Slow

DATA

ENTRY

CS RECEIVER 1 FORMAT

5

Universal High Speed

B

SIA

C

Ademco Point ID

E

Pager

USER AREA OPTIONS - Select the desired Area Options (Area 1 and Area 2) from the table below.

DATA ENTRIES

OPTION ENABLED

L

R

EXPLANATION

blank(•)

blank(•)

Disabled

User Code not active in this area.

blank(•)

1

Arm/Disarm

Allows User Code to arm/disarm this area.

blank(•)

2

Arm Only

Prevents User Code from disarming this area.

blank(•)

3

Service

A Service Code has restricted arm/disarm rights; if an area is armed with a Service Code, the area can be disarmed
with any valid User Code, including a Service Code. If the area is armed with OTHER than a Service Code, it CANNOT
be disarmed with a Service Code.

blank(•)

4

Access

This is normally used to activate a door striker while an area is disarmed. Also program “Access Control on PGM2
Output” (Address 0719) and “PGM2 Output Access Control Timeout” (Address 0711).

blank(•)

Add 8

* User Program

User Program Option is enabled for Keypad 1 only, wherever it is connected (Area 1 or Area 2).

User #

User Code

Area 1

Area2

Options

Options

NOTE: When entering the Area 1 and
Area 2 options, press

G0

for a

ten. Enter

0

for a blank.